Searched for "40101700"
Enclosed fan relay type 184, 24-Volt coil, SPNO-SPNC. Used for switching Solenoids, fan motors and general purpose switching. UL file number E12139 CSA file number LR13360.
- Coil-voltage 24-Volt
- Normally opened / closed type
- 1/4 in. spade connections 5 pin
- Coils frequency 50 Hz/60 Hz
The Emerson 90-244 2 pole is a definite purpose contactor for air conditioning and heating equipment. This contactor features low VA coil for cooler operation. The universal mounting bracket fits existing mounting holes. 24 VAC. 30 Amp.
- Low voltage coil for increased life
- Quiet operation
- Universal mounting bracket fits most applications
- Double break contacts ensure positive make and break
- 24-Volt AC
- Resistance DC OHMS 11
- Current MA 150
- Nominal VA 6
- Maximum inrush VA 32
24-Volt Heat Sequencer, fan and electric, 2 Switches. On Timings, 30-90 seconds. Off timings 1-30 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). UL component recognized.
- Direct replacement for most fan / heat sequencing functions
- 2 switches
- On timings: 30-90 seconds
- Off timings: 1-30 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads
The Emerson 24A34 series electric heat sequencer is a direct replAcement for most fan and heat sequencing functions. This electric heat sequencer features 2 switches and multi-poise mounting. 24 volt input control.
- Terminal markings are equivalent to other types
- 24-Volt input control
- Multi-poise mounting
- Double quick-connect terminals for combination loads
- 1 switch
- On timings 30 - 90 seconds
- Off timings 1 - 30 seconds
Supply your technicians with only the best components to get the job done the right way the first time. These contactors are manufactured from the highest quality materials. Backed by designs that are tried and tested to perform.
- Accordance with U.L. bulletin no. 508 Industrial control equipment, contactors meet specifications for devices up to 600 VAC
- Coils have class B insulation
- Includes lug, spade terminals, and covers
- Single pole include shunt
This definite purpose contactor meets UL508 specifications for devices up to 600 Vac. The coils have class B insulation. It includes lugs, spade terminals and covers.
- 180/150/120 locked rotor Amps
- 30 inductive Amps
- 40 resistive Amps
- Auxiliary switches sold separately
- Time delay relay. 24 volt coil
- On: 1-25 seconds. Off: 65-115 seconds
- Replacement for Goodman B13707-38
The Emerson 24A34-3 Electric Heat Sequencer is a direct replacement for most fan/heat sequencing functions. This sequencer features 2 switches and multi-poise mounting. This sequencer features 2 switches and multi-poise mounting.
- Direct replacement for most fan / heat sequencing functions
- 2 switches
- On timings: 1-20 sec
- Off timings: 40-110 sec
- 24-Volt input control
Enclosed fan relay type 84, 24-Volt coil, SPNO. Used for switching Solenoids, fan motors and general purpose switching. UL file number E12139 CSA file number LR13360.
- Coil-voltage 24-Volt
- Switch action single pole, normally open
- Coils frequency 50 Hz/60 Hz
- Spade connections
24-Volt Heat Sequencer. Fan and electric, 1 switch. On timings, 1-20 Seconds. Off timings 40-110 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). 24-Volt input control Multi-pose mounting Any contacts (except M1 and M) can be used as auxiliary contacts Double quick-connect terminals for combination loads Ambient Temperature Rating: -50 to +165 degree F UL component recognized.
- Direct replacement for most fan / heat sequencing functions
- 1 switch
- On timings: 30-90 seconds
- Off timings: 1-30 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads
This is a genuine Goodman replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- SEQUENCER B12565-52
- HVAC application
- Dimensions: 4 in. x 23.75 in. x 30.75 in.
- Quality build
This is a genuine Goodman replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- Sequencer B12565-51
- HVAC application
- Dimensions: 0.99 in. x 0.99 in. x 0.99 in.
- Quality build
The Emerson two pole double throw semi-enclosed relay for use in vending machines, appliances, heating and air conditioning applications, and general-purpose switching. This is a switching relay is a 2 Pole relay with 24 VAC coil. This Type 91 relay features DPDT switching and two sets of power rated contacts.
- Easy install
- -40 degree F to 130 degree F temperature range
- Coil voltage 24 Hz
- Coil DC resistance 17.5
- Coil MA 334
- Coil nominal VA 9.5
- Coil inrush VA 22
A very durable contacted that is capable of carrying more amperage. Manufactured with quality material that ensures a good direct contact so the device can function properly. This contactor works with 99% of residential AC units.
- 40 inductive Amps
- 50 resistive Amps
- 240/200/160 locked rotor Amps
- Auxiliary switches sold separately
Fasco Condenser Fan Motor
- 1/4 HP
- 208 / 230 Volts
- 1075 RPM
- 1-Speed
- 1.8 Amps
- Totally Enclosed
- Reversible Rotation
- POC5 Capacitor
- Sleeve Bearings
- 5.6" Diameter
- 1.2 Load Factor
- Stud/Belly Band/Tapped Holes Mounting
- 1.00 Service Factor
- 6-1/2" Shaft Length
- Permanent Split Capacitor Motor Type
- 48 Frame
- Automatic Overload
- 1 Phase
- 1/2" Shaft Diameter
- 1 Shaft
- 60 Hertz
- 1/2" x 6-1/2" Shaft Dimension
- 4" Length Less Shaft
The Emerson 90-290Q through 90-295Q relays for switching single or two speed fan motors, solenoids, relays, resistive loads, and general-purpose switching. This fan relay features a compact, totally enclosed design, which provides quiet, reliable and economical operation. This relay has SPNO switching. 24 VAC.
- Compact and fully enclosed design
- Quiet operation
- SPDT
- 208/240 VAC coil
- Resistance DC OHMS 90
- Coil nominal current MA 125
- Coil nominal VA sealed 3
- Inrush VA 4
This is a genuine GOODMAN replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- HVAC application
- Dimensions: 11.25 in. x 8 in. x 0.5 in.
- For use with GOODMAN and Amana equipment
- PCB, defrost control
E Lite is a plastic pad designed as a mounting base for condenser equipment. E Lite is injection molded from polypropylene, resulting in a pad that is lightweight, but durable. A subtle texture prevents unit slide and presents a classic appearance which is enhanced by rounded edges.
- Generous individually engineered ribbing for optimum self-leveling ground support
- Each pad is molded with its size in raised letters for easy identification
- Rugged design provides uniform and generous ribbing for optimum self-leveling ground support without inserts
- E Lite is drillable for securing unit
- Does not crack, flake or warp when tested per ASTM D2299 with refrigerants, synthetic canine urine, compressor oil or salt solution (of 20% by volume)
- Flawless performance under the 25-cycle regime specified by ASTM C67
- DiversiTechs most popular pad due to its rugged durability, strength and clean looks
These definite purpose contactors meet UL508 specifications for devices up to 600 Vac.All single pole include shunt. It also inludes lugs, spade terminals and covers.The coils have class B insulation.
- Definite purpose contactors
- 30 inductive Amps
- 40 resistive Amps
- Auxiliary switches sold separately
The GOODMAN 2-Ton Upflow/Downflow Evaporator Coil 14 in. Wide Model CAPFA2318A6 is equipped with advanced features that ensure the comfort of your space. These features range from the 21 in. depth for easier attic access to an all-aluminum evaporator coil. The evaporator coil is also furnished with foil-faced insulation that covers the internal casing to reduce cabinet condensation. These are the features that make the GOODMAN evaporator coil a worthwhile investment.
- Compact and lightweight all-aluminum evaporator coil with AlumaFin7 technology
- Optimized for use with R-410A refrigerant
- Check flowrator for cooling and heat pump applications
- Vertical application
- 21" depth for easier attic access
- Foil-faced insulation covers the internal casing to reduce cabinet condensation
- AHRI certified
- ETL listed
- Galvanized, leather grain-embossed finish
- Galvanized, leather grain-embossed finish
Eaton offers the most complete line of Definite Purpose (DP) contactors in the industry. Designed for heating, ventilation, air conditioning and refrigeration (HVACR) applications, Eatons DP contactors are designed to handle the most challenging installations. Eatons DP Contactors offer an efficient design with low VA coil ratings and straight-through wiring.
- These ampere and horsepower rated devices from Eatons electrical sector are subjected to stringent quality assurance inspections and testing procedures
- 15-360a contractors ratings
- Single-, 2-, 3- and 4 pole configurations
- Open components and enclosed designs available
The Emerson 90-370 heavy-duty general-purpose relay for heating and cooling applications and general switching. This is a totally enclosed relay, which operates in any position. This relay provides general-purpose switching for heating and cooling applications.
- SPDT
- 24V VAC coil, 50/60hz
- Resistive DC OHMS 77
- Coil nominal current MA 125
- Coil nominal VA sealed 3
- Inrush VA 4
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 2-ton
- 10-KW electric heat
- 208/240-Volt
- Piston metering
Fasco Condenser Motor
- 1/5 H.P.
- 208-230 Volts
- 1.3 Amps
- CW Rotation
- POC5 Capacitor
- 1075 RPM
- Sleeve Bearings
- 5-5/8" Diameter
- Totally-Enclosed Enclosure
- Stud Mounting
- 4-1/8" Shaft Length
- Permanent Split Capacitor Motor Type
- 48 Frame
- Automatic Overload
- 1 Phase
- 1/2" Shaft Diameter
- 60 Hertz
- 1/2" x 4-1/8" Shaft Dimension
- 3-3/4" Length Less Shaft